The Milwaukee digital BRIX refractometer is temperature compensated with a 0 to 85 percent BRIX range and +/- 0.2 percent accuracy. It is easy to use with simple two button operation and fast with a response time under 2 seconds. Maintenance is a breeze also with an easy-to-clean sealed flint glass prism and stainless steel well.DESIGN FEATURESFast, accurate results with digital dual level LCD readout. Easy measurement with just 2-3 drops of sample needed and results less than 2 seconds. Simple one-point calibration using distilled or deionized water. Easy to clean, stainless steel sample well with unit rated to IP65 as "dust tight" and protected against water jets. Battery percent level indicator with automatic shut-off (batteries included). Ideal for winemakers, brewers, fruit and vegetable growers, maple syrup producers, and food producers. The measurement technique and temperature compensation employ methodology recommended in the ICUMSA Methods Book (Internationally recognized body for Sugar Analysis).
The perfect solution to store and hydrate your Bluelab pH products. Bluelab pH Probe KCl Storage Solution is made specifically for use with Bluelab pH products. It is designed to increase response time and maximize the life of Bluelab pH pens and pH probes. For best results, use the KCl solution to store the pH pen/probe after use and hydrate monthly. Bluelab pH Probe KCl Storage Solution is manufactured to high laboratory standards.
COM-300 Replacement ProbeSpecifications(Replacement pH/EC/TDS/TEMP Sensor for COM-300)Measures pH, Conductivity(EC), TDS, and TempMeasures TemperatureProbe: ABS materialStainless steel sensor pinsThermometer: YesGlass pH sensor with reference tubeCap with a sponge is included for storage solution
HM-500 HydroMaster: EC/TDS, pH, Temp Continuous MonitorThe HM-500 is the most versatile continuous monitor indicating EC/TDS, pH, and Temp providing accurate, stable readings the user can rely on. With its rechargeable battery this unit is portable or can be wall mounted.. To make is even more user friendly, it comes equipped with touch screen, high and low alarm set points, and recorded readings. It is ideal for hydroponics and other applications such as lab, pools, aquariums etc.FeaturesContinuous pH/EC/TDS/Temp MonitorRechargeable batteryRF ResistantPortable/Wall Mount/BenchtopData Storage: Up to 20 measurement readingsAuto Shut-Off: After 5 minutesAlarm: Adjustable High & Low Set Point and on/offDisplay: LCD Touch-Type Screen with Auto Back lightingProbe: ABS with Platinum electrodes for EC / Single Junction pH SensorThree Year WarrantySpecificationsMeasurement ScalespH: pHTemp: °C, °FTDS: ppm (0.5 / ppm (0.7) / ppt (0.5) / ppt (0.7)EC: µS / mSRange: pH: 0.00 – 14.00 pHTemperature: 0.0 – 80.0 °C / 32.0 – 176 °FTDS: 0 – 9999 ppm / 0 – 10.00 pptEC: 0 – 9999 µS / 0 – 20.00 mSResolution:pH: 0.1 pHTemp: 0.1°C / 0.1 °FTDS: ppm: 0.1ppm (0 – 99.9ppm) / 1 ppm (100-999ppm) / 10ppm (1000-9990 ppm) ppt: 0.01 ppt (0.01 – 10.00 ppt)EC: µS: 0.1 µS (0 – 99.9 µS) / 1 uS (100 – 999 µS) / 10µS (1000-9990 µS) mS: 0.01 mS (0.01 – 20.00 mS)ATC: YesAccuracy: pH: ± 0.1 pHTemp: ± 1 °C / °FTDS: ± 2 %EC: ± 2 %Power Source: AC 110 V – 220V / Rechargeable Lithium Ion BatteryFunction Environment: 0 – 50°C (0-122°C) / RH 80 % (EC Probe: 0 – 80°C)Sensor Cable: 24-inch shielded Coaxial CableDimensions: About 8 x 4 x 1.5 inchesWeight: 15.2 ounces for body / 5 ounces for two probes (without case)
The COM-360 is a professional grade level pH/EC/TDS/Temp meter ideal for all water quality testing, hydroponics, water purification applications, wastewater regulation, aquaculture, colloidal silver, labs & scientific testing, pools & spas, ecology testing, boilers & cooling towers, water treatment and more.
Features
Measures Potential Hydrogen (pH), Electrical Conductivity (EC), Total Dissolved Solids (TDS), and Temperature
Five scales: pH, µS, mS, ppm 0.5 (NaCl) Scale & 0.7 (442) Scale
Automatic Temperature Compensation (ATC) using three temperature coefficients
Water-resistant housing
Digital Calibration (push button) to any point within the meter’s range
Auto-off function, data-hold function, and low-battery indicator
Display: large and easy-to-read LCD screen includes simultaneous temperature reading
Replaceable Sensor (model SP-CP)
Factory Calibrated (pH/EC/TDS)
Includes translucent cap, 2 (AAA) alkaline batteries, pH 4 & 7 calibration solutions, pH storage solution and lanyard
Specifications
pH Range: 0 – 14 pH
EC Range: 0 – 9990 µS; 0 – 9.99 mS
TDS Range: 0 – 8560 ppm (0.7 Scale); 0 – 5000 ppm (0.5 Scale)
Temperature Range: 0-55 °C; 32-130°F
Resolution:
pH: 0.1pH
EC 0 – 999 : 1μS ; 1000 – 9990 : μS ; 0- 9.99 mS :0.01 mS
TDS 0 – 999 : 1ppm / 1000 – 9990: 10 ppm
Temperature 0.1 °C/°F
Accuracy: +/- 2%
EC to TDS Conversion Factor: Non-linear conversions for KCl, 442TM or NaCl solutions, selected by the user.
Probe: Detachable platinum electrodes & pH glass sensor with reference tube electrodes
Housing: Water resistant
Power source: 2 x Triple-A (AAA) included
Dimensions: 20.0 x 3.4 x 3.4 cm (7.8 x 1.3 x 1.3 inches)
Weight:110g (4.0 oz)
442 is a registered trademark of the Myron L Company.
KCI Storage Solution. Traceable to NIST standard. Close immediately after use. Store between 15-25 °C. Do not return liquid. Thoroughly rinse the electrode before and after each use. Pour some KCI storage solution into the electrode's protective cover. Place the electrode in the solution.
Sold as a case of 8 bottles.
500 ml pH 4,01 calibration solution. Traceable to NIST standard. Close immediately after use. Store between 15-25 °C. Do not return liquid.
Sold as a case of 8 bottles.
500 ml pH 7,00 calibration solution. Traceable to NIST standard. Close immediately after use. Store between 15-25 °C. Do not return liquid.
Sold as a case of 8 bottles.
500 ml EC 1413 calibration solution. Traceable to NIST standard. Close immediately after use. Store between 15-25 °C. Do not return liquid.
Sold as a case of 8 bottles.
KCI Storage Solution. Traceable to NIST standard. Close immediately after use. Store between 15-25 °C. Do not return liquid. Thoroughly rinse the electrode before and after each use. Pour some KCI storage solution into the electrode's protective cover. Place the electrode in the solution.
Sold as a case of 18 bottles.
100 ml pH 4,01 calibration solution. Traceable to NIST standard. Close immediately after use. Store between 15-25 °C. Do not return liquid.
Sold as a case of 18 bottles.
100 ml pH 7,00 calibration solution. Traceable to NIST standard. Close immediately after use. Store between 15-25 °C. Do not return liquid.
Sold as a case of 18 bottles.